Kitchen electrical load is the expected peak electrical demand of every appliance and fitting in the kitchen, and the only safe way to work with it is to calculate it, then engage a Licensed Electrical Worker before changing anything on the circuit. Inventory your appliances, work out the demand, and confirm that RCCB protection and a Certificate of Compliance are in place before any new point goes live.
TL;DR:
- Kitchen circuits must be sized based on calculated maximum demand with appropriate diversity, especially for appliances over 3 kW that require dedicated circuits.
- Continuous loads like warmers and refrigeration should be sized at 125% of their running current, and starting currents for motorized equipment must be factored into load calculations.
- Licensed Electrical Workers must supervise any wiring modifications, certify installations, and ensure RCCB sensitivity and protection comply with EMA guidance.
- Proper labeling of circuits and thorough load planning prevent overloading, void warranties, and protect insurance coverage during future upgrades or faults.
- Always prepare appliance wattage, existing breaker ratings, and spare capacity details before site visits to avoid multiple trips and costly rework.
Table of Contents
- Understanding watts, amps, maximum demand and the 125% rule
- Calculating your kitchen load step by step
- Typical kitchen circuits and the minimums worth planning for
- Safety, certification and what your LEW is legally required to do
- What to prepare before your LEW or contractor arrives
- How efficient commercial appliances change your load planning
- What experience on site actually teaches you
- Equipment built for high-demand cooklines
- FAQ
- Sources
Understanding watts, amps, maximum demand and the 125% rule
Before you add up a single appliance, you need four concepts straight. Nameplate wattage tells you energy use, not current draw, so you convert it to amps using the supply voltage; in most kitchens, that means dividing watts by 230 for single-phase circuits. Connected load (every appliance’s wattage added together) is almost never the same figure as maximum demand, because kitchens rarely run everything at once. Diversity accounts for that gap.
Continuous loads, such as a food warmer running for hours, are treated differently from loads that cycle on and off.
- Watts to amps: amps = watts ÷ 230 for a standard single-phase circuit.
- Connected load vs maximum demand: sum of all nameplate ratings vs the realistic peak when diversity is applied.
- The 125% rule: for a continuous load, size the circuit at 125% of the running current to allow for sustained heat build-up, so a 16 A continuous draw calls for a 20 A circuit.
- Starting currents: motorised and induction appliances can draw several times their running current for a brief moment at switch-on, which protective devices must tolerate without tripping.
Calculating your kitchen load step by step
A load calculation is arithmetic, but the sequence matters. Skip a step and you either under-size the circuit or pay for capacity you never use.
- List every appliance with its nameplate wattage and how often it actually runs at the same time as the others; a domestic oven and a kettle rarely peak together, but a commercial fryer line often does.
- Convert each wattage to amps using amps = watts ÷ 230, rounding up to the nearest whole amp rather than down.
- Apply diversity factors to reflect realistic simultaneous use rather than a worst-case sum of everything switched on at once.
- Add the 125% multiplier to any continuous load, such as warmers, water heaters or extended-run refrigeration compressors.
- Allow for starting currents on motorised or induction equipment, either by adding a fixed percentage buffer to that circuit’s rating or, for heavy items, giving it its own dedicated circuit so inrush does not interact with anything else.
- Compare the result to standard breaker sizes (commonly 16 A, 20 A or 32 A for single appliances) and to the distribution board’s remaining capacity.
Say a kitchen has a 3,500 W induction cooker, a 2,000 W oven and a 1,200 W extractor fan, all expected to run together during service. That is 6,700 W connected, which converts to roughly 29 A (6,700 ÷ 230).
When the calculated demand sits close to an existing breaker’s rated capacity, that is your signal to escalate rather than to proceed on your own judgement.
Pro Tip: Treat any appliance over 3 kW as a candidate for its own dedicated circuit rather than folding it into a shared one.

Typical kitchen circuits and the minimums worth planning for
Most kitchens, domestic or commercial, settle into a recognisable circuit pattern once the load calculation is done.
- Two small-appliance circuits, commonly rated at 20 A each, covering countertop equipment like kettles, mixers and toasters that rotate in and out of use.
- Dedicated circuits for induction hobs, ovens, deep fryers and other high-draw equipment, sized individually rather than shared.
- Separate lighting and extractor fan circuits, kept apart from appliance loads so a tripped breaker in the cookline does not leave the room dark.
- A refrigeration circuit on its own protection, since compressors run continuously and should not share a breaker that might trip from an unrelated fault.
- Spare ways on the distribution board, left deliberately unused, so a future appliance does not force a full board replacement.
Clear labelling at the DB, matching each breaker to the circuit it feeds, saves time on every future fault or upgrade and is worth insisting on even when it adds a line to the contractor’s invoice.
Safety, certification and what your LEW is legally required to do
Any wiring work, new socket outlet or distribution board change must be carried out or supervised by a Licensed Electrical Worker, a requirement set out in EMA guidance on engaging licensed workers. The LEW inspects and certifies the installation before supply is restored or turned on, and that inspection is not optional paperwork, it is the mechanism that confirms the approved load and protection settings for your specific site.
- RCCB sensitivity: final circuits with lower approved loads should carry high-sensitivity residual-current protection, with thresholds set according to EMA guidance and as determined by the Licensed Electrical Worker, per single-line diagram and RCCB guidance.
- Licence class thresholds: installations with higher approved electrical loads require engagement of the appropriate class of Licensed Electrical Worker or may require an installation licence, in accordance with regulatory thresholds.
- Documentation to collect: a Certificate of Compliance, a signed single-line diagram, and a Letter of Authorisation where licensed work is subcontracted.
RCCB and ELCB protection is central to EMA’s electrical safety guidance, which also warns against overloading power points, a common root cause of kitchen electrical faults. The Electricity Act reinforces this by requiring that any modified installation be inspected, tested and certified by the appropriate class of licensed worker, and it restricts certain wiring choices, including aluminium conductors in domestic installations.
What to prepare before your LEW or contractor arrives
A short checklist before any site visit saves a second trip and a second invoice.
- Record every appliance’s nameplate wattage, the existing DB labelling, and any breaker that has tripped repeatedly in the past.
- Ask the LEW directly about the board’s approved load, how many spare ways remain, and whether the single-line diagram will be updated to reflect the change.
- Request proof of licence on ELISE, a written estimate covering cable runs and DB work specifically, and confirmation that a Certificate of Compliance will be issued on completion.
- Ask about likely cost drivers, since a DB upgrade, a longer cable run, or a permit submission each adds separate time and expense to a straightforward quote.
How efficient commercial appliances change your load planning
Energy-efficient appliances cut continuous running load, which helps your electricity bill, but several still pull a significant starting current, so plan the circuit for the spike, not just the average draw.
- Induction cookers in the 3,500 W to 5,000 W range, such as the Induction Cooker 5000W, need their current converted to amps and usually warrant a dedicated circuit.
- Convection ovens, like the Electric Convection Oven, have a steadier draw than induction but still belong on the load list rather than assumed as negligible.
- Grant eligibility and running-cost savings are worth weighing alongside electrical sizing, and a showroom visit lets you compare ratings before committing a circuit to a specific model.
What experience on site actually teaches you
The mistake we see most often is designing for today’s appliance list and leaving no spare capacity for tomorrow’s. Label every circuit at the point of installation, not months later from memory, and never assume a board has room without checking the single-line diagram. A DIY change to wiring or protection voids more than a warranty: it can void insurance cover and breach the Electricity Act’s certification requirements.
— David
Equipment built for high-demand cooklines
We supply commercial kitchen equipment with load planning considered from the start. For cooklines running sustained high heat, the Heavy Duty Kwali Induction and the wider induction cooker range are built for exactly the kind of continuous, high-wattage demand this guide walks through.
- We provide information to help you match appliance specification sheets to your calculated load before ordering, so the circuit decision is made with real numbers.
- Our range covers induction cookers, ovens and specialised equipment including the Tabletop Large Electric Kebab Machine and the Standing Electric Kebab Machine, both worth factoring into a load calculation for a busy kitchen.
- Grant eligibility for energy-efficient models is a procurement factor that can be discussed alongside the technical specification.
Visit our full equipment collection or get in touch for a product demonstration and a specification sheet before your next kitchen fit-out.
FAQ
How do I calculate the electrical load of a house?
You list every circuit’s connected appliances, convert their wattage to amps, then apply diversity factors so the figure reflects realistic simultaneous use rather than a worst-case total. A Licensed Electrical Worker confirms the final approved load against your actual supply and board capacity, as set out in EMA’s guidance on engaging licensed workers.
How many electrical circuits does a kitchen typically need?
A typical kitchen runs at least two small-appliance circuits, separate dedicated circuits for high-draw equipment like ovens and induction hobs, and standalone circuits for lighting, the extractor fan and refrigeration. The exact count depends on the appliance list and the simultaneous-use pattern you calculate.
What is the 125% rule in electrical wiring?
A 16 A continuous draw, for example, calls for a circuit rated at 20 A rather than exactly 16 A.
How many amps does my kitchen or house need?
There is no single fixed figure: amperage requirements depend on your full appliance inventory, diversity factors and whether any loads are continuous or carry high starting currents. A Licensed Electrical Worker calculates and certifies the final approved load for your specific installation, referencing RCCB and single-line diagram requirements along the way.
Do I really need a licensed electrician for a small kitchen change?
Yes: the Electricity Act requires that any modified electrical installation be inspected, tested and certified by the appropriate class of licensed worker, regardless of how minor the change looks. Skipping this step risks both safety and the validity of your Certificate of Compliance.