Energy monitoring in a commercial kitchen means measuring how much electricity each major piece of equipment uses, so you can find avoidable waste and confirm that an upgrade has lowered your bill. The routine is simple: set a baseline, measure the largest loads, act on the hot spots, and compare the results with the baseline. Monitoring shows you where the money goes. Replacing the equipment responsible for the largest loads is what lowers the bill, and in Singapore that replacement may qualify for grant support.
This guide is written for restaurant owners, caterers, food manufacturers, new food entrepreneurs and kitchen managers. It explains each step and where it usually goes wrong.
TL;DR
- Start with a baseline: your electricity bills and any meter data over a full year, adjusted for sales volume.
- Measure the biggest loads first: refrigeration, cooking equipment, and air conditioning or ventilation.
- Walk the kitchen, then confirm suspected waste with spot measurements or data loggers.
- Replace the equipment that the data shows is the largest and least efficient load. Singapore’s Energy Efficiency Grant (EEG) can support such purchases.
- Repeat the comparison against your baseline at least once a year to confirm the savings.
Table of Contents
- What energy monitoring involves
- Where a kitchen’s energy goes
- How to set up monitoring, step by step
- Reading the data to find avoidable waste
- Changes to make once you know your hot spots
- Confirming that a change worked
- Equipment that fits the monitoring result
- Our perspective
- FAQ
- Sources
What energy monitoring involves
Monitoring has three parts: a baseline, ongoing measurement, and review.
The baseline is a quantified picture of your consumption before you change anything. Enterprise Singapore’s food sector guide states that the initial energy audit establishes this baseline, and that SMEs should repeat audits annually to assess whether the solutions are working. The audit starts from metered electricity data obtained from your energy provider.
Ongoing measurement means tracking consumption over time rather than reading a single monthly bill. A monthly bill tells you the total. It does not tell you whether the walk-in chiller, the fryers or the air conditioning caused a rise.
Review means comparing results against the baseline and against sales. The same Enterprise Singapore guidance notes that combining audit data with sales figures adjusts for swings in volume. A busy month will always use more energy, so the useful measure is energy per unit of output, such as kWh per 1,000 covers or per tonne produced.

Where a kitchen’s energy goes
Before you buy a single meter, it helps to know which systems usually dominate. The figures below come from studies in other countries, so use them to decide where to look first, not as a prediction for your own premises.
| Source | Setting | Largest loads found |
|---|---|---|
| US Energy Information Administration, 2018 | US food service buildings | Cooking 40%, refrigeration 15%, space heating 12% |
| Mudie et al., International Journal of Low-Carbon Technologies | 14 UK pub restaurants | Refrigeration about 41% of kitchen electricity, then fryers 13%, combi-ovens 12%, grills 12%, bain maries 9% |
The two sets of figures differ because they measure different things. The US figure covers all energy in a building, including gas. The UK study metered kitchen electricity only. Both point the same way: refrigeration and cooking equipment make up most of the load.
Singapore food manufacturers have a similar pattern. The National Environment Agency’s best practice guide for food manufacturing plants lists chilled-water cooling, refrigeration, compressed air, production motors and lighting as the main electrical uses. It puts compressed air alone at about 7% of total electrical energy.
The UK study also found that behaviour and maintenance matter. It estimated potential savings of 70% from behavioural factors and 45% from poor maintenance in the loads it examined. Equipment left on between services and poorly maintained units are visible in monitoring data long before they appear as a repair bill.
How to set up monitoring, step by step
1. Collect a year of bills and note your output
Gather 12 months of electricity bills, and record covers served, meals produced or production weight for each month. A full year captures seasonal swings in cooling demand and trade. Where it goes wrong: using only the last three months, which may be unusually quiet or busy.
2. Walk through the kitchen
The NEA’s energy measurement and audit guidance begins with a walk-through to inspect each energy-consuming system by eye. Note each item’s rated power, its operating hours and whether it is running when it need not be. Typical findings include chillers set colder than the food requires, fryers kept at temperature through slack periods, and cold-room doors left open.
3. List your equipment by expected load
Rank equipment by rated power multiplied by hours of use. Refrigeration runs 24 hours a day, so a mid-sized unit can outweigh a high-powered appliance used for two hours. This ranking decides where meters go first.
4. Measure the largest loads
The same NEA guidance describes using spot measurements and data loggers to verify and quantify wastage, such as over-cooled spaces or excessive operating hours, and to reconcile your energy accounts with the actual loads. For a small kitchen, plug-in power meters on individual appliances and a clamp meter on dedicated circuits are enough. For a larger site, permanent sub-meters on the distribution board give continuous data by circuit.
A California study of 91 plug-load appliances at 29 foodservice sites found daily use ranging from 0.6 to 20.4 kWh per appliance. Appliances of the same type differed widely, which is why measuring beats relying on nameplate ratings.
5. Use a simple efficiency indicator
For refrigeration, the NEA’s assessment framework for food manufacturing plants defines a specific energy consumption indicator: the refrigeration system’s daily kWh divided by the weight of material stored or by the refrigerated volume. Tracking one ratio like this shows drift in performance that the raw kWh figure hides.
6. Record at regular intervals
Read meters at the same time each week, or use loggers that record every 15 minutes. Interval data shows what runs overnight and during closed hours, which is where much avoidable use sits. A spreadsheet with weekly kWh, sales and the ratio between them is enough to start.
Reading the data to find avoidable waste
The NEA guidance says to compare consumption with design figures and industry benchmarks, then verify suspected waste with measurements. In a kitchen this turns into a short list of questions:
- What is the overnight load? After closing, only refrigeration, and anything deliberately left on, should draw power. Anything else is a candidate for switching off.
- How do similar units compare? Two chillers of the same size with different consumption point to a fault, a worn door seal or a poor location.
- Does consumption follow sales? If energy stays flat while sales fall, equipment is idling at full power.
- Is cooling working too hard? Over-cooled spaces are a waste the NEA specifically names.
The NEA also describes a more detailed Level II audit. It adds short-term metering and logging, breaks energy use into major sub-systems, evaluates month-to-month variation, and estimates the retrofit cost and energy cost savings for each measure. That level of detail suits food manufacturers and larger multi-outlet operators. For a single restaurant, the walk-through and meters on the top three loads usually answer the practical questions.
Monitoring across several outlets adds a further benefit. Interval data lets you compare sites against each other and see which one is out of line. For a worked example of quantified results from an audit and retrofit programme, see these commercial HVAC retrofit results.
Changes to make once you know your hot spots
Monitoring only pays when it leads to action. These changes are the ones that the evidence supports.
Cooking equipment
Enterprise Singapore’s guide describes Springleaf Prata Place switching from gas to induction hobs with the Energy Efficiency Grant. The guide reports utility bills down by up to 15% at some outlets, emissions down by about 20% and more consistent cooking temperatures. A US study of submetered kitchens, Energy Reduction in Commercial Kitchens, found that replacing standard fryers with efficient models saved 40% to 50% of fryer energy.
If your monitoring shows cooking equipment at the top of the list, compare the options in our guides on induction versus gas cookers and open burner versus induction for a Singapore kitchen. For ovens, there are no-capital-spend steps for cutting oven energy.
Refrigeration
Refrigeration runs continuously, so small gains accumulate. The NEA’s food manufacturing guide calculates that raising compressor suction pressure or lowering condensing pressure saves 3% to 5% of compressor power per degree Celsius. In its worked example, resetting a -36°C cold-room set point to -33°C on a 200 RT system saves about 315,360 kWh a year. That is an industrial example, but the principle applies to smaller units: do not run cold storage colder than the product requires, keep doors closed, and fit door alarms. Food safety temperatures still apply, so any set point change must keep the product within the required range.
For layout and equipment choices, read our notes on restaurant refrigeration layout, energy-efficient commercial refrigerators and commercial freezer energy use.
Ventilation and air conditioning
The same US study found that a demand-controlled kitchen ventilation system cut fan energy from 72.1 to 39.0 kWh a day, a reduction of 46%. Enterprise Singapore’s guide also recommends smart controls such as sensors, thermostats and demand-side management for air conditioning and lighting.
Lighting and small appliances
LEDs are the quickest and cheapest change. Our article on reducing restaurant energy bills sets out the order: LEDs first, equipment upgrades under the EEG afterwards. The California study found the strongest savings in espresso machines, coffee brewers, conveyor toasters and holding cabinets, averaging US$200 to US$300 per replaced unit.
Confirming that a change worked
A change has worked only if consumption fell once you account for sales. The check is straightforward:
- Take the baseline period’s kWh and output before the change.
- Record the same measures for the same months after the change, to allow for seasonal weather.
- Compare kWh per unit of output, not total kWh.
- Repeat the audit annually, as Enterprise Singapore advises for SMEs.
The US Environmental Protection Agency’s ENERGY STAR guide for commercial kitchens recommends tracking energy and water use over time to verify efficiency improvements. Larger properties show what sustained tracking achieves. Marina Bay Sands’ UFI award case study reports 164 electricity and BTU sub-meters with a real-time dashboard and a 29% reduction in chilled-water energy in 2014 against a 2012 baseline. The investment was over S$180,000, with an estimated two-year payback. A single kitchen does not need that scale. The method of baseline, measure and compare is the same.
Equipment that fits the monitoring result
Monitoring usually ends in an equipment decision: which unit is costing the most, and what should replace it. We supply energy-efficient refrigerators, chillers and freezers, fryers, ovens, induction cookers, food warmers, hot plates and stainless steel fittings for restaurants, caterers and food manufacturers in Singapore. Our guidance covers claiming government energy efficiency grants. Our own position is that eligible purchases can attract grants of up to 70% of the original cost, and that our energy-efficient products can save up to 40% on electricity bills. You can see the range in our showroom or browse the full equipment collections. The Energy Efficiency Grant page explains the grant process, and our article on restaurant energy audits in Singapore covers how audit findings feed into an application.
If your data points to cooking, the heavy duty kwali induction and standing induction cooker are the models to look at first.
Our perspective
Most kitchens we talk to already know their monthly bill. What they lack is a view of which machine produces it. A few weeks of measurement on the refrigeration, the fryers and the cooking line usually settles the question of where to spend first.
We focus on energy-efficient equipment because it addresses the largest loads directly. A refrigeration unit or cooker that uses less power does so every hour it runs, without asking the kitchen team to change how they work. That is why we pair products with guidance on the Energy Efficiency Grant: the grant reduces the upfront cost of the equipment that monitoring identifies as the priority.
Our advice is to measure first, rank the loads, and then plan replacements in that order. Our energy audit guide for Singapore kitchens and our article on buying energy-efficient kitchen equipment first set out that sequence in more detail.
David
FAQ
How often should a commercial kitchen review its energy use?
Enterprise Singapore advises SMEs to repeat energy audits annually to assess whether their solutions are effective. Between audits, a weekly or monthly reading of the main meters shows problems sooner. Review again after any equipment change.
Which equipment should I monitor first?
Start with refrigeration and cooking equipment. International studies of food service premises find these two groups account for the largest shares of energy, and refrigeration runs around the clock. Air conditioning and ventilation come next.
Do I need permanent sub-meters, or are portable meters enough?
For one kitchen, plug-in power meters and clamp meters on key circuits give the data needed for a first review. Permanent sub-meters by circuit suit larger sites and multi-outlet operators, because they record continuously and show trends. The NEA’s audit guidance describes both spot measurements and data loggers.
Why compare energy with sales and not just the bill?
Bills rise and fall with trade. Enterprise Singapore notes that integrating audit data with sales figures adjusts for volume fluctuations, so you can target real hot spots. Energy per cover or per tonne is the fairer measure.
Can the Energy Efficiency Grant help once monitoring shows a problem?
In the Enterprise Singapore guide, Springleaf Prata Place used the Energy Efficiency Grant to switch from gas to induction hobs. Our guidance on the grant, including the support of up to 70% of the original cost, is on our EEG page. Current eligibility and funding terms are set by the official scheme, so check them there before you apply.
Sources
- Enterprise Singapore, Food and companies guide
- US Energy Information Administration, food service buildings
- Electricity use in the commercial kitchen, International Journal of Low-Carbon Technologies
- NEA, best practice guide for food manufacturing plants
- NEA, assessment framework for food manufacturing plants
- NEA, energy measurement and audit
- California Energy Commission, electric plug load savings potential
- Energy Reduction in Commercial Kitchens
- ENERGY STAR guide for commercial kitchens
- UFI case study, Marina Bay Sands